Begin at the table edge you can actually use. Measure from the planned position of the stand’s base to the point where its holder would grip your stenomask while you are seated and dictating. Measure horizontally, sideways and vertically. Then trace the route the arm will have to take around the table, laptop and exhibits. Martel specifies a 33-inch flexible arm and a desk clamp that fits surfaces up to 2.75 inches thick. Neither measurement, on its own, tells you whether the mask will reach you.
If the holder would have to travel farther than the arm length even by a direct route, choose another mounting point. If the direct distance is close to the published length, test the stand at the actual desk before relying on that position. An arm has to bend to bring a mask to its working angle. A buyer who leaves room to make that bend has a more realistic plan than one who expects the mask to sit exactly 33 inches from the edge.
The Martel hands-free stenomask Flex Stand, SKU 191, has a clamp for the work surface and a separate spring clamp for a Martel mask. The distinction matters when measuring. One end must seat on the furniture. The other must meet the mask where the holder can grip it, with the reporter able to speak, see the witness and reach the record controls.
Martel equipment in this guide

Find the position you would choose without a stand
Sit down first. Put the chair where you would use it for a deposition and set the laptop where you can read it. Hold your own stenomask and dictate a sentence at your ordinary working level. Look toward an imaginary witness, return to the screen and pick up a pen. A seated position that works for all three is a useful starting point. Measuring with the chair pushed under the table can produce a beautifully precise number for a position you never occupy.
Ask a colleague to note where the holder would meet the body of the mask. They can observe from the side while you continue to hold it. If you are measuring alone, pause, remove the mask and use the position of your chin as a rough landmark on the first sketch. Then return to your working position and refine the estimate using the holder location. Your nose, the front edge of the mouthpiece and the point gripped by the stand are three different places. Using a different one each time can make two otherwise sound measurements disagree.
Write down the distance from the front table edge to the closest part of your chair or another convenient landmark. Record the chair-height setting in a way you can reproduce. These are reference measurements for the rehearsal. You are free to adjust them. Their purpose is to let you say, for example, that a second attempt worked with the same seat location and a different base position. Without that detail, an improvement attributed to the stand may simply be the result of moving your whole body toward it.
Now watch what happens when you read a few lines from a printed page. Does your usual paper position require you to turn away from the screen? Does the last line disappear behind the mask when you glance down? The expected working position may be a small region rather than a single point. Draw that region on the sketch. The task is to put the stenomask within easy reach of that region while preserving the movements that let you follow testimony.
Inspect the mounting edge before measuring the reach
Choose a section of edge with an accessible top and underside. Examine it from the side at the exact point you propose to use. The measurement that matters is the material the jaws would have to span there. An overhang can have a modest top thickness and a deep supporting apron farther back. Conversely, a thick decorative edge can hide a different profile below the exposed lip. A ruler held in the middle of the tabletop does not answer either question.
Take three notes. How thick is the edge at the contact point? Is there room underneath for the lower part of the clamp? Is the furniture suitable and available for clamping? A surface can meet the 2.75-inch published limit and still offer too little clearance to seat the base. Permission to use a desk can depend on the room and the furniture. Ask the person who controls the space when the answer affects your setup. A nearby stable surface may provide an equally good route.
Trace the vertical profile without assuming that the underside follows the top. Look for a sloping edge, a frame that blocks the clamp, an adjacent chair arm or equipment mounted beneath the table. A base that sits flush when the table is empty may project into the reporter’s leg space after the chair moves in. Check from both the reporter’s side and the aisle side. An acceptable position should preserve ordinary use of the surrounding furniture.
If every accessible point on the near edge has a deep apron, consider the end of the table or a permitted nearby work surface. Mark each candidate on your drawing with ordinary names such as “left end,” “near right edge” and “side desk.” Using real positions makes the drawing usable when the room changes. “Position one” is easily forgotten by the time a room coordinator asks which chair or edge you meant.
Measure across, to the side and upward
Pick a candidate base position. Mark it on the sketch at the point where the arm would leave the base. With the mask held where you dictate, identify the location where its spring holder would sit. Think of an imaginary straight line between those two points. If the observer can measure that line directly with a tape without interfering with the reporter’s face, record it. Otherwise, take component measurements and use those to estimate it.
Start with the horizontal distance into or away from the table. Then measure how far the mask-holder position is displaced sideways from the chosen edge location. Finally, measure how far the holder position is above or below the point where the arm starts. All three contribute to the distance the arm must cover. Write the vertical difference between endpoints rather than the height of your chair or the height of the desk from the floor. The stand connects the endpoints, not two separate measurements to the carpet.
In a fictional measuring exercise, the working position is 18 inches out from the base, 8 inches to the side and 12 inches higher. The horizontal diagonal is about 19.7 inches. Including the height difference gives a direct endpoint distance of about 23.1 inches. A reader who enjoys using a calculator can square each of the three measurements, add the squares and take the square root of the total. Measuring the direct diagonal physically serves the same purpose. This example describes an imaginary layout and a geometric estimate. A real stand still has to assume a usable shape within the space.
A second fictional arrangement has a 30-inch horizontal offset and a 14-inch rise, with no sideways offset. Its diagonal is just over 33 inches. The tape measure on the table might lead the reporter to believe the arm has three inches to spare. The rise uses that apparent margin. This is a reason to look for a nearer base location before ordering for that particular layout. It is not evidence of actual loaded stand performance in any specific deposition room.
A sketch can be more valuable than a formula in a crowded room. Draw the table from above, trace the outward and sideways distances and label the height difference next to the holder. Add the edge of the opened screen. Make one side view showing the base and the top of the screen. The same direct distance can lead to different practical choices if one route runs clear and the other intersects a screen or a raised exhibit holder.
Allow room for the bend that presents the mask
The 33-inch dimension describes the arm. The useful horizontal or diagonal reach depends on where the ends are and how the arm bends between them. A short curve near the mask may help the holder point in the right direction. A turn near the base may move the arm away from a binder. Both changes use some of the available length. The published specification does not give a universal working radius for every bend or a guaranteed distance under every load.
For a preliminary reach check, use a nonstretching cord or paper strip 33 inches long. This is a reader-led geometry exercise. Ask one person to hold one end near the proposed base location while the seated reporter identifies the holder location. Form a gentle route with the cord that stays clear of the screen and papers. Keep it away from anyone’s face. If there is no route without pulling the cord straight across something, change the proposed base position. The cord represents length only. It cannot demonstrate clamp fit, arm stiffness, holding force or mask orientation under load.
Look at the last few inches of the proposed route from the side. Imagine the holder attached there and the body of the mask projecting beyond it. Which way will the cord from the microphone exit? Will the stand present the mask toward the reporter or make the reporter turn toward it? A route that ends directly in front of you may still approach from an angle that leaves very little room for the spring clamp. Trace a second curve from one side and see what it changes.
With the actual stand, follow the product instructions and position it on the approved surface. Support your own mask while inserting it in the holder. Observe it after you remove your hand. Decide whether it stays where your working position calls for it and whether it can be returned there after an ordinary movement. If that position requires an extreme arrangement that you cannot reproduce comfortably, move the base closer or change the route. You do not need to calculate a bend radius to recognize when a layout is impractical for your own work.
Give the witness, the screen and the exhibits their own space
Stand reach competes with things the reporter must see. At your rehearsal desk, put a person or a visible marker where the witness would be. Dictate into the mask and look up from the screen. Note whether the stand crosses your view of the witness’s face or hides the person introducing an exhibit. Then look down at the part of the screen where your working text appears. Lowering the arm in one place may clear either view without moving the mask itself.
Lay out the largest document you reasonably expect to handle. If it would ordinarily arrive from your left, have a colleague hand you a blank sheet from that side. Leave the mask in the working position while you accept the sheet, inspect the top line, put it down and return to the controls. A stand can pass the reach measurement while occupying the only useful exchange area. Sometimes moving the base a short distance toward the end preserves the handoff and changes the mask position very little.
Give room microphones their own locations. Follow the separate plan for recording speech in the room. A mask stand supports the reporter’s stenomask; adding a flexible arm does not change which speaker a particular microphone is intended to capture. If the arm would pass immediately beside a room microphone or the reporter’s paperwork, make a fictional practice recording while moving that paperwork. Listen for contact noises and compare the saved result with a pass in which the sheet is handed farther away.